FLAMEX® PANTO LEAD-FREE 26/45 kV
FLAMEX® PANTO LEAD-FREE 26/45 kV
FLAMEX
MEDIUM VOLTAGE ROOF CABLES
For inside and outside use in railway vehicles. Installation in cable ducts or tubes. Available on request: HV loop, completely pre-assembled flexible cables with plugs and sealing ends, electrically tested.
FLAMEX® PANTO LEAD-FREE 50mm²
Nexans ref. 79470574
- Embalaje: Cut to length (m)
- Sección del conductor: 50 mm²
- Screen section: 16 mm²
- Diámetro sobre semi-conductora externa: 29,0 mm
- Diámetro exterior mínimo: 34,0 mm
- Diámetro exterior máximo: 36,0 mm
- Peso aproximado: 2100 kg/km
FLAMEX® PANTO LEAD-FREE 95mm²
Nexans ref. 79470575
- Embalaje: Cut to length (m)
- Sección del conductor: 95 mm²
- Screen section: 16 mm²
- Diámetro sobre semi-conductora externa: 32,0 mm
- Diámetro exterior mínimo: 40,0 mm
- Diámetro exterior máximo: 42,0 mm
- Peso aproximado: 2500 kg/km
FLAMEX® PANTO LEAD-FREE 150mm²
Nexans ref. 79470576
- Embalaje: Cut to length (m)
- Sección del conductor: 150 mm²
- Screen section: 16 mm²
- Diámetro sobre semi-conductora externa: 36,0 mm
- Diámetro exterior mínimo: 41,0 mm
- Diámetro exterior máximo: 43,0 mm
- Peso aproximado: 3200 kg/km
FLAMEX® PANTO LEAD-FREE 185mm²
Nexans ref. 79477903
- Embalaje: Cut to length (m)
- Sección del conductor: 185 mm²
- Screen section: 25 mm²
- Diámetro sobre semi-conductora externa: 37,0 mm
- Diámetro exterior mínimo: 42,0 mm
- Diámetro exterior máximo: 44,0 mm
- Peso aproximado: 3600 kg/km
FLAMEX® PANTO LEAD-FREE 240mm²
Nexans ref. 79470577
- Embalaje: Cut to length (m)
- Sección del conductor: 240 mm²
- Screen section: 25 mm²
- Diámetro sobre semi-conductora externa: 40,0 mm
- Diámetro exterior mínimo: 45,0 mm
- Diámetro exterior máximo: 48,0 mm
- Peso aproximado: 4300 kg/km
Descripción
Descripción
Estándares
-
ProductoEN 45545-2 (HL3); EN 50264-1; IEC 60502
DESIGN
1. Conductor: Flexible stranded tinned copper, class 5 acc. to IEC 60228
2. Inner semi-conductive layer: Conductive rubber
3. Insulation: Cross-linked compound type EI 110 acc. to EN 50264-1
4. Outer conductive layer: Conductive rubber easy to strip
5. Screen: Conductive tape + tinned single wires with separator
6. Outer sheath: Cross-linked compound type EM104 acc. to EN 50264-1. Oil, diesel, ozone and UV resistant. Colour: black
Example of cable marking: FLAMEX PANTO – LEAD FREE - 1x [conductor nominal cross section] / [geometrical screen cross-section] 26/45kV I LYNXEO I WEEK/YEAR batch-no
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Bending radius:
- Static use: 5 x outer cable diameter
- For installation and occasional movements: 10 x outer cable diameter
Características
Características
Características de construcción
Características de construcción
Características eléctricas
Características eléctricas
Características de uso
Características de uso
Nuestros sitios web
Selecciona tu país para conocer nuestros productos y soluciones
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania