Nexans H07Z1-K Easybox 1G6 Verde-Amarillo 100m
Nexans H07Z1-K Easybox 1G6 Verde-Amarillo 100m
Cable de alta seguridad libre de halógenos, para cableado de cuadros eléctricos e instalaciones en locales de pública concurrencia.
Lee más- Nexans ref. : 10286830
Descripción
Descripción
Estándares
-
ProductoEN 50525-3-31; EN 50575; IEC 60228; UNE 21022; UNE 211002
-
EnsayoEN 50266-2-4; EN 50267-2-2; IEC 60332-1; IEC 60332-3-24; IEC 61034-2; NF C32-070/C2; UNE EN 50267-2-3 ; UNE-EN 50265-2-1
Application
Flexible insulated conductors Nexans H07Z1-K are used for fixed secured protected installation.
Halogen free, fire retardant with low emission of smoke, Nexans H07Z1-K may be used in public buildings or areas where fire safety is concerned
Installation
Nexans H07Z1-K can be installed in open air, in conduit, in cable ducting, in switch cabinets.
Thanks to the sliding properties of the insulation, installation is made easier while pulling in...
Encuentra este producto en EASYCALC™
Nuevo embalaje en cartón para Nexans H07V-K y ALSECURE H07Z1-K
Código de colores para identificar la sección del cable
Colores de cables disponibles
-
-
Características
Características
Características de construcción
Características de construcción
Características dimensionales
Características dimensionales
Características eléctricas
Características eléctricas
Características mecánicas
Características mecánicas
Características de uso
Características de uso
Recursos
Recursos
Documentación
Current capacity table PVC insulation multicore three phase
Sección del conductor | A2 - Multi-core cable in conduit in a thermally insulated wall | B2 - Multi-core cable in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | E - Multi-core cable in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
Sección del conductor 6.0 |
A2 - Multi-core cable in conduit in a thermally insulated wall
29.0 |
B2 - Multi-core cable in conduit on a wooden wall
23.0 |
C - Single-core or multi-core cable on a wooden wall
34.0 |
D1 - Single-core or Multi-core cable in ducts in the ground
27.0 |
D2 - Single-core or Multi-core cables designed to be buried directly in the ground
41.0 |
E - Multi-core cable in free air
32.0 |
mm² 38.0 |
Cu 30.0 |
Al 41.0 |
Cu 0.0 |
Al 43.0 |
Cu 33.0 |
Current capacity table PVC insulation multicore single phase
Sección del conductor | A2 - Multi-core cable in conduit in a thermally insulated wall | B2 - Multi-core cable in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | E - Multi-core cable in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
Sección del conductor 6.0 |
A2 - Multi-core cable in conduit in a thermally insulated wall
32.0 |
B2 - Multi-core cable in conduit on a wooden wall
25.0 |
C - Single-core or multi-core cable on a wooden wall
38.0 |
D1 - Single-core or Multi-core cable in ducts in the ground
30.0 |
D2 - Single-core or Multi-core cables designed to be buried directly in the ground
46.0 |
E - Multi-core cable in free air
36.0 |
mm² 46.0 |
Cu 36.0 |
Al 48.0 |
Cu 0.0 |
Al 51.0 |
Cu 39.0 |
Current capacity table PVC insulation single core three phase
Sección del conductor | A1 - Insulated conductors in conduit in a thermally insulated wall | B1 - Insulated conductors in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | F - Single-core flat cables, touching in free air | Ft - Single-core trefoil cables, touching in free air | G - Single-core horizontal spaced | Gv - Single-core flat vertical spaced | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
Sección del conductor 6.0 |
A1 - Insulated conductors in conduit in a thermally insulated wall
31.0 |
B1 - Insulated conductors in conduit on a wooden wall
24.0 |
C - Single-core or multi-core cable on a wooden wall
36.0 |
D1 - Single-core or Multi-core cable in ducts in the ground
28.0 |
D2 - Single-core or Multi-core cables designed to be buried directly in the ground
41.0 |
F - Single-core flat cables, touching in free air
32.0 |
Ft - Single-core trefoil cables, touching in free air
38.0 |
G - Single-core horizontal spaced
30.0 |
Gv - Single-core flat vertical spaced
41.0 |
mm² 0.0 |
Cu 0.0 |
Al 0.0 |
Cu 0.0 |
Al 0.0 |
Cu 0.0 |
Al 0.0 |
Cu 0.0 |
Al 0.0 |
Current capacity table PVC insulation single core single phase
Sección del conductor | A1 - Insulated conductors in conduit in a thermally insulated wall | B1 - Insulated conductors in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | F - Single-core flat cables, touching in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
Sección del conductor 6.0 |
A1 - Insulated conductors in conduit in a thermally insulated wall
34.0 |
B1 - Insulated conductors in conduit on a wooden wall
26.0 |
C - Single-core or multi-core cable on a wooden wall
41.0 |
D1 - Single-core or Multi-core cable in ducts in the ground
32.0 |
D2 - Single-core or Multi-core cables designed to be buried directly in the ground
46.0 |
F - Single-core flat cables, touching in free air
36.0 |
mm² 46.0 |
Cu 36.0 |
Al 48.0 |
Cu 0.0 |
Al 0.0 |
Cu 0.0 |
Selling & delivery Information
Ink jet marking
USE - HAR- ALSECURE H07Z1-K (AS) TYPE 2 AENOR PLANT N° NEXANS – DAY YEAR
Declaración de desempeño
- Declaration of Performance n� : 1000150-FRAU
- Certification Date : 21/3/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 1+
- Notified body : NB 099
- Declared performance : Cca-s1b,d1,a1