ALSECURE® H07Z1-K (AS), 1G50 mm²,verde-amarillo
ALSECURE® H07Z1-K (AS), 1G50 mm²,verde-amarillo
Cable de alta seguridad libre de halógenos, para cableado de cuadros eléctricos e instalaciones en locales de pública concurrencia.
Lee más- Nexans ref. : 10100015
- País de referencia : 336
Descripción
Descripción
Estándares
-
ProductoEN 50525-3-31; EN 50575; IEC 60228; UNE 21022; UNE 211002
-
EnsayoEN 50266-2-4; EN 50267-2-2; IEC 60332-1; IEC 60332-3-24; IEC 61034-2; NF C32-070/C2; UNE EN 50267-2-3 ; UNE-EN 50265-2-1
Application
Flexible insulated conductors Nexans H07Z1-K are used for fixed secured protected installation.
Halogen free, fire retardant with low emission of smoke, Nexans H07Z1-K may be used in public buildings or areas where fire safety is concerned
Installation
Nexans H07Z1-K can be installed in open air, in conduit, in cable ducting, in switch cabinets.
Thanks to the sliding properties of the insulation, installation is made easier while pulling in...
Encuentra este producto en EASYCALC™
Nuevo embalaje en cartón para Nexans H07V-K y ALSECURE H07Z1-K
Código de colores para identificar la sección del cable
Colores de cables disponibles
-
-
Características
Características
Características de construcción
Características de construcción
Características dimensionales
Características dimensionales
Características eléctricas
Características eléctricas
Características mecánicas
Características mecánicas
Características de uso
Características de uso
Recursos
Recursos
Documentación
Current capacity table PVC insulation multicore three phase
Sección del conductor | A2 - Multi-core cable in conduit in a thermally insulated wall | B2 - Multi-core cable in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | E - Multi-core cable in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
Sección del conductor 50.0 |
A2 - Multi-core cable in conduit in a thermally insulated wall
99.0 |
B2 - Multi-core cable in conduit on a wooden wall
78.0 |
C - Single-core or multi-core cable on a wooden wall
118.0 |
D1 - Single-core or Multi-core cable in ducts in the ground
92.0 |
D2 - Single-core or Multi-core cables designed to be buried directly in the ground
144.0 |
E - Multi-core cable in free air
110.0 |
mm² 116.0 |
Cu 91.0 |
Al 130.0 |
Cu 99.0 |
Al 153.0 |
Cu 117.0 |
Current capacity table PVC insulation multicore single phase
Sección del conductor | A2 - Multi-core cable in conduit in a thermally insulated wall | B2 - Multi-core cable in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | E - Multi-core cable in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
Sección del conductor 50.0 |
A2 - Multi-core cable in conduit in a thermally insulated wall
110.0 |
B2 - Multi-core cable in conduit on a wooden wall
86.0 |
C - Single-core or multi-core cable on a wooden wall
133.0 |
D1 - Single-core or Multi-core cable in ducts in the ground
104.0 |
D2 - Single-core or Multi-core cables designed to be buried directly in the ground
168.0 |
E - Multi-core cable in free air
125.0 |
mm² 140.0 |
Cu 109.0 |
Al 156.0 |
Cu 117.0 |
Al 180.0 |
Cu 135.0 |
Current capacity table PVC insulation single core three phase
Sección del conductor | A1 - Insulated conductors in conduit in a thermally insulated wall | B1 - Insulated conductors in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | F - Single-core flat cables, touching in free air | Ft - Single-core trefoil cables, touching in free air | G - Single-core horizontal spaced | Gv - Single-core flat vertical spaced | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
Sección del conductor 50.0 |
A1 - Insulated conductors in conduit in a thermally insulated wall
106.0 |
B1 - Insulated conductors in conduit on a wooden wall
84.0 |
C - Single-core or multi-core cable on a wooden wall
134.0 |
D1 - Single-core or Multi-core cable in ducts in the ground
104.0 |
D2 - Single-core or Multi-core cables designed to be buried directly in the ground
144.0 |
F - Single-core flat cables, touching in free air
110.0 |
Ft - Single-core trefoil cables, touching in free air
116.0 |
G - Single-core horizontal spaced
91.0 |
Gv - Single-core flat vertical spaced
130.0 |
mm² 99.0 |
Cu 174.0 |
Al 133.0 |
Cu 167.0 |
Al 219.0 |
Cu 128.0 |
Al 169.0 |
Cu 197.0 |
Al 152.0 |
Current capacity table PVC insulation single core single phase
Sección del conductor | A1 - Insulated conductors in conduit in a thermally insulated wall | B1 - Insulated conductors in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | F - Single-core flat cables, touching in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
Sección del conductor 50.0 |
A1 - Insulated conductors in conduit in a thermally insulated wall
119.0 |
B1 - Insulated conductors in conduit on a wooden wall
93.0 |
C - Single-core or multi-core cable on a wooden wall
151.0 |
D1 - Single-core or Multi-core cable in ducts in the ground
118.0 |
D2 - Single-core or Multi-core cables designed to be buried directly in the ground
168.0 |
F - Single-core flat cables, touching in free air
125.0 |
mm² 140.0 |
Cu 109.0 |
Al 156.0 |
Cu 117.0 |
Al 196.0 |
Cu 149.0 |
Selling & delivery Information
Ink jet marking
USE - HAR- ALSECURE H07Z1-K (AS) TYPE 2 AENOR PLANT N° NEXANS – DAY YEAR