ALSECURE® H07Z1-K (AS), 1x35 mm², azul

Descripción

Descripción

Estándares

  • Producto
    EN 50525-3-31; EN 50575; IEC 60228; UNE 21022; UNE 211002
  • Ensayo
    EN 50266-2-4; EN 50267-2-2; IEC 60332-1; IEC 60332-3-24; IEC 61034-2; NF C32-070/C2; UNE EN 50267-2-3 ; UNE-EN 50265-2-1

Application

Flexible insulated conductors Nexans H07Z1-K are used for fixed secured protected installation.
Halogen free, fire retardant with low emission of smoke, Nexans H07Z1-K may be used in public buildings or areas where fire safety is concerned

Installation

Nexans H07Z1-K can be installed in open air, in conduit, in cable ducting, in switch cabinets.
Thanks to the sliding properties of the insulation, installation is made easier while pulling in...
 

Encuentra este producto en EASYCALC™

Nuevo embalaje en cartón para Nexans H07V-K y ALSECURE H07Z1-K

Código de colores para identificar la sección del cable

Colores de cables disponibles

-

-

Características

Características

Características de construcción

Características de construcción

Aislamiento
Sin halógeno, TI 7 según EN 50363-7
Flexibilidad del conductor
Flexible, Clase 5
Material del conductor
Cobre desnudo
Libre de plomo
Libre de halógenos
Con conductor amarillo/verde
No
Con neutro de sección reducida
No
Forma del conductor
Circular
Insulation colour
Negro

Características dimensionales

Características dimensionales

Sección del conductor
35 mm²
Diámetro exterior
- mm
Neutral conductor section (when smaller)
- mm²
Número de conductores
1
Peso aproximado
35 kg/km

Características eléctricas

Características eléctricas

Tensión nominal de servicio Uo/U
450/750 V
Intensidad admisible al aire libre
- A
Maximum operating voltage
750 V
Resistencia máxima del conductor en CC a 20º C
- Ohm/km
Test voltage
2500 V

Características mecánicas

Características mecánicas

Flexibilidad del cable
Flexible
Resistencia mecánica a impactos
Baja

Características de uso

Características de uso

Temperatura máxima del conductor
70 °C
No propagador del incendio
EN IEC 60332-3-24 (cat C)
No propagación de la llama
UNE-EN 50265-2-1
Densidad de los humos
EN 50268-2
Embalaje
Rollos
Estanqueidad
Limited
Resistencia a la intemperie
Restricted, not ozon stable
Resistencia química
Restricted to oil, acid & base
Temperatura máxima operativa
70 °C

Recursos

Recursos

Documentación

Current capacity table PVC insulation multicore three phase

Sección del conductor A2 - Multi-core cable in conduit in a thermally insulated wall B2 - Multi-core cable in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground E - Multi-core cable in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
35.0 83.0 65.0 99.0 77.0 119.0 90.0 98.0 77.0 110.0 83.0 126.0 96.0

Current capacity table PVC insulation multicore single phase

Sección del conductor A2 - Multi-core cable in conduit in a thermally insulated wall B2 - Multi-core cable in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground E - Multi-core cable in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
35.0 92.0 71.0 111.0 86.0 138.0 103.0 119.0 93.0 132.0 98.0 148.0 111.0

Current capacity table PVC insulation single core three phase

Sección del conductor A1 - Insulated conductors in conduit in a thermally insulated wall B1 - Insulated conductors in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground F - Single-core flat cables, touching in free air Ft - Single-core trefoil cables, touching in free air G - Single-core horizontal spaced Gv - Single-core flat vertical spaced
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
35.0 89.0 70.0 110.0 86.0 119.0 90.0 98.0 77.0 110.0 83.0 143.0 109.0 137.0 181.0 105.0 139.0 162.0 124.0

Current capacity table PVC insulation single core single phase

Sección del conductor A1 - Insulated conductors in conduit in a thermally insulated wall B1 - Insulated conductors in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground F - Single-core flat cables, touching in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
35.0 99.0 77.0 125.0 97.0 138.0 103.0 119.0 93.0 132.0 98.0 162.0 122.0

Selling & delivery Information

Ink jet marking
USE - HAR- ALSECURE H07Z1-K (AS) TYPE 2 AENOR PLANT N° NEXANS – DAY YEAR

Contáctanos

Temas sobre los que desea recibir mayor información

Campos requeridos

Por favor revise la data ingresada e intente nuevamente

El correo debe contener este símbolo @

Protección de data personal

Tiene el derecho de rechazar el procesamiento de sus datos personales y/o su uso para propósitos comerciales

¡Gracias!

Gracias por contactarse con nosotros. Nos pondremos en contacto pronto.

Error

Ocurrió un error. Por favor intentar nuevamente

Cerrar