Nexans H05VVF 2x1,5 WHITE C10m

Descripción

Descripción

Estándares

  • Producto
    EN 50525-2-11; HD 21.5; IEC 60227-53; NF C32-201/5

Application

H05VV-F cables are designed for households. They can only be used for heating and cooking appliances if there is no risk of radiations or contact with hot parts.

Installation

Open air.

 

Marking

n (x or G) s mm² S.Y + USE HAR H05VV-F N° Usine

  • n = number of cores
  • s = section in mm²
  • G = with Green-Yellow
  • x = without Green-Yellow

Características

Características

Características de construcción

Características de construcción

Con conductor amarillo/verde
No
Color de cubierta
Blanco
Aislamiento
PVC
Con neutro de sección reducida
No
Cubierta exterior
PVC
Flexibilidad del conductor
Flexible, Clase 5
Forma del conductor
Circular
Libre de plomo
Material del conductor
Cobre desnudo

Características dimensionales

Características dimensionales

Sección del conductor
1,5 mm²
Número de conductores
2
Diámetro exterior máximo
- mm
Neutral conductor section (when smaller)
- mm²
Peso aproximado
- kg/km

Características eléctricas

Características eléctricas

Tensión nominal de servicio Uo/U
300/500 V
Caída de tensión, mono-fase
- V/A.km
Intensidad admisible al aire libre
- A

Características mecánicas

Características mecánicas

Resistencia mecánica a impactos
Baja
Flexibilidad del cable
Flexible

Características de uso

Características de uso

Temperatura máxima del conductor
70 °C
Embalaje
Rollos
Longitud
10 m
Temperatura máxima del conductor en corto-circuito
150 °C
Temperatura ambiente de utilización (rango)
-5 ... 60 °C
No propagación de la llama
C2, NF C 32-070
Resistencia a la intemperie
AN1
Resistencia química
Accidental
Estanqueidad
Accidental
Radio de curvatura mínimo en operación estática
- mm

Recursos

Recursos

Documentación

Current capacity table PVC insulation multicore single phase

Sección del conductor A2 - Multi-core cable in conduit in a thermally insulated wall B2 - Multi-core cable in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground E - Multi-core cable in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
1.5 14.0 0.0 16.5 0.0 19.5 0.0 22.0 0.0 22.0 0.0 22.0 0.0

Current capacity table PVC insulation multicore three phase

Sección del conductor A2 - Multi-core cable in conduit in a thermally insulated wall B2 - Multi-core cable in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground E - Multi-core cable in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
1.5 13.0 0.0 15.0 0.0 17.5 0.0 18.0 0.0 19.0 0.0 18.5 0.0

Declaración de desempeño

  • Declaration of Performance n� : 1000138-FRLV
  • Certification Date : 11/10/17
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 1812
  • Declared performance : Eca

Contáctanos

Temas sobre los que desea recibir mayor información

Campos requeridos

Por favor revise la data ingresada e intente nuevamente

El correo debe contener este símbolo @

Protección de data personal

Tiene el derecho de rechazar el procesamiento de sus datos personales y/o su uso para propósitos comerciales

¡Gracias!

Gracias por contactarse con nosotros. Nos pondremos en contacto pronto.

Error

Ocurrió un error. Por favor intentar nuevamente

Cerrar