Description

Description

Standards

  • International
    EN 50525-2-31
  • National
    UNE 21022; UNE 21031-3

Application

The H07V-K cable is a single-pole flexible copper cable (class 5) with insulation for fixed installations or in closed analog systems. It is also suitable for protected installations, lighting and switchgear. The cable is installed in conduit, in dry areas. It is often used for industrial and commercial electrical installations.

The H07V-K cable has a class 5 flexible copper conductor, which offers good electrical conductivity, with cross-sections from 1.5 mm² to 35 mm².

The conductor of the H07V-K cable is insulated with a shock and abrasion resistant PVC sheath, which protects against the effects of vibrations and mechanical movements.

 

Installation

The rated voltage of the H07V-K cable is 450/750 V, which makes it suitable for a wide range of domestic and industrial applications.

H07V-K cable is commonly used to supply electrical equipment such as heaters, lighting systems, power distribution cabinets, power generation and transformation equipment, air-conditioning installations, etc.
The H07V-K cable complies with international standards HD 21.3, EN 50525-2-31 and IEC 60227-2, ensuring its safety and reliability in electrical installations complying with these standards.
 

Thanks to its flexibility and sliding properties of the insulation, the installation of the cable is made easier and it is very suitable for installations with complex layouts.

 

Marking

SY+ USE < HAR > H07V-K Plant n° 

Nexans H07V-K Easybox: Nueva solución en cartón del cable H07V-K para las secciones 1.5, 2.5, 4 y 6 mm².

Nexans EasyCalc

New cardboard solution, Nexans H07V-K Easybox

Colour code for new Nexans H07V-K Easybox

Cable colors available

-

-

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Flexible class 5
Conductor material
Bare copper
Insulation
PVC
Lead free
Yes
Conductor shape
Circular
Sheath colour
Black
With Green/Yellow core
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Approximate weight
65 kg/km
Conductor cross-section
6 mm²
Nominal outer diameter
6.3 mm
Number of cores
1
Neutral conductor section (when smaller)
- mm²
Outer Diameter
6.3 mm

Electrical characteristics

Electrical characteristics

Permissible current (one phase)
41.0 A
Permissible current rating (3 conductors)
36.0 A
Rated Voltage Uo/U (Um)
450/750 V
Max. DC resistance of the conductor at 20°C
- Ohm/km
Permissible current rating in open air
- A
Permissible current rating when buried
29 A

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Flexible
Mechanical resistance to impacts
Low

Usage characteristics

Usage characteristics

Length
7200 m
Chemical resistance
Accidental
Flame retardant
EN 50265-2-1
Laying operation bending radius
37.8 mm
Max. conductor temperature in service
70 °C
Minimum static operating bending radius
18.9 mm
Oil resistance
Yes
Operating temperature, range
-5 ... 60 °C
Packaging
Pallet
Short-circuit max. conductor temperature
160 °C
Water proof
Accidental
Weather resistance
Good
Fire retardant
EN IEC 60332-3-24 (cat C)

Resources

Resources

Documentation

Current capacity table PVC insulation single core three phase

Conductor cross-section A1 - Insulated conductors in conduit in a thermally insulated wall B1 - Insulated conductors in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground F - Single-core flat cables, touching in free air Ft - Single-core trefoil cables, touching in free air G - Single-core horizontal spaced Gv - Single-core flat vertical spaced
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
6.0 31.0 24.0 36.0 28.0 41.0 32.0 38.0 30.0 41.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Current capacity table PVC insulation single core single phase

Conductor cross-section A1 - Insulated conductors in conduit in a thermally insulated wall B1 - Insulated conductors in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground F - Single-core flat cables, touching in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
6.0 34.0 26.0 41.0 32.0 46.0 36.0 46.0 36.0 48.0 0.0 0.0 0.0

Declaration of Performance

  • Declaration of Performance n� : 1000020-FRAU-107
  • Certification Date : 3/22/23
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : NB 1722
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close