SIWO-KUL S30 1x240 12 kV BK

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092
  • Test
    IEC 60331; IEC 60332-1; IEC 60332-3-22; IEC 60332-3-24; IEC 60754-1; IEC 60754-2; IEC 61034

Application

  • Connection of rotating machines windings, like motors, alternators, generators.
  • Cabling of static devices, like power converters, motor drives, power cabinets, transformers
  • Adapted for wind turbines, marine and offshore, rollingstock, photovoltaic, energy storage systems

Construction

  • Flexible tin-plated copper conductor class 5 as per IEC 60228, other class in option
  • High grade silicon rubber insulation
  • Tin platted Cu braid for EMC protection screen
  • Silicone outer sheath
  • Inner and outer co-extruded semi-conductor reduces partial discharge and increases cable life

Properties

  • Partial discharge < 10 pC
  • Operating temperature in continuous mode -55°C to +180°C
  • Resistance to thermal shocks

 

  • Type approval certificate : Lloyds Register LR21139304TA
  • Type approval certificate : BV Marine & Offshore 09555/D0 BV, file : ACE 01/723/01

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tinned copper
Conductor flexibility
Flexible class 5
Insulation
Special Silicone
Halogen free
Yes
Outer sheath
Synthetic yarn braiding
Construction type
1120 x 0.5

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
240 mm²
Nominal outer diameter
37.8 mm
Approximate weight
2938 kg/km
Conductor diameter
21.8 mm

Electrical characteristics

Electrical characteristics

Operating voltage
12 kV
Test voltage
31 kV
Max. DC resistance of the conductor at 20°C
0.082 Ohm/km
Breakdown voltage
50 kV
Breakdown field strength (kV/mm)
> 20
Loss factor tan d
< 10-2
Dielectric constant ER
3 ... 4

Mechanical characteristics

Mechanical characteristics

Minimum Tensile Strength
8 MPa
Cable flexibility
Flexible
Elongation at break of insulation (%)
> 250

Usage characteristics

Usage characteristics

Minimum static operating bending radius
186 mm
Operating temperature, range
-55 ... 180 °C
Chemical resistance
Good
Oil resistance
Yes
Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3
Fire resistant
IEC 60331
Gases corrosivity
IEC 60754-1; IEC 60754-2
Smoke density
IEC 61034
Packaging
Cut to length

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close