Nexans SIWO-KUL® S30 12 kV

Products

SIWO-KUL S30 1x16 12 kV BK

Nexans ref. 60012646

  • Packaging: Cut to length (m)
  • Conductor cross-section: 16 mm²
  • Nominal outer diameter: 21.8 mm

 

SIWO-KUL S30 1x25 12 kV BK

Nexans ref. 10207759

  • Packaging: Cut to length (m)
  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: 21.9 mm

 

SIWO-KUL S30 1x35 12 kV BK

Nexans ref. 10549497

  • Packaging: Cut to length (m)
  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 24.2 mm

 

SIWO-KUL S30 1x50 12 kV BK

Nexans ref. 10224688

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 25.9 mm

 

SIWO-KUL S30 1x70 12 kV BK

Nexans ref. 10560244

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 27.9 mm

 

SIWO-KUL S30 1x95 12 kV BK

Nexans ref. 60011923

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 29.6 mm

 

SIWO-KUL S30 1x120 12 kV BK

Nexans ref. 10567757

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 31.5 mm

 

SIWO-KUL S30 1x150 12 kV BK

Nexans ref. 60500694

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 34.9 mm

 

SIWO-KUL S30 1x185 12 kV BK

Nexans ref. 60500695

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 35.6 mm

 

SIWO-KUL S30 1x240 12 kV BK

Nexans ref. 60012240

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 37.8 mm

 

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092
  • Test
    IEC 60331; IEC 60332-1; IEC 60332-3-22; IEC 60332-3-24; IEC 60754-1; IEC 60754-2; IEC 61034

Application

  • Connection of rotating machines windings, like motors, alternators, generators.
  • Cabling of static devices, like power converters, motor drives, power cabinets, transformers
  • Adapted for wind turbines, marine and offshore, rollingstock, photovoltaic, energy storage systems

Construction

  • Flexible tin-plated copper conductor class 5 as per IEC 60228, other class in option
  • High grade silicon rubber insulation
  • Tin platted Cu braid for EMC protection screen
  • Silicone outer sheath
  • Inner and outer co-extruded semi-conductor reduces partial discharge and increases cable life

Properties

  • Partial discharge < 10 pC
  • Operating temperature in continuous mode -55°C to +180°C
  • Resistance to thermal shocks

 

  • Type approval certificate : Lloyds Register LR21139304TA
  • Type approval certificate : BV Marine & Offshore 09555/D0 BV, file : ACE 01/723/01

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
Yes

Electrical characteristics

Electrical characteristics

Operating voltage
12 kV

Usage characteristics

Usage characteristics

Operating temperature, range
-55 ... 180 °C
Chemical resistance
Good
Oil resistance
Yes
Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3
Fire resistant
IEC 60331
Gases corrosivity
IEC 60754-1; IEC 60754-2
Smoke density
IEC 61034

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error