FLAMEX® EN 50264-3-1 M 600V
FLAMEX® EN 50264-3-1 M 600V
FLAMEX
SINGLE CORE POWER CABLES
FLAMEX® EN 50264-3-1 600V M power cables are used for fixed and protected installations. This product range is recommended for narrow spaces where an optimal bending radius is required. FLAMEX® cables are designed to withstand tough working conditions (oil, ozone, temperature variation, etc.). 120°C conductor temperature is allowed for a 20,000 hours cumulative working time.
FLAMEX EN 50264-3-1 600V 1 M
Nexans ref. 79462201
- Packaging: Spool (1000m)
- Conductor cross-section: 1 mm²
- Minimum outer diameter: 2.5 mm
- Maximum outer diameter: 2.7 mm
- Approximate weight: 14 kg/km
FLAMEX EN 50264-3-1 600V 1.5 M
Nexans ref. 79462301
- Packaging: Spool (1000m)
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 2.8 mm
- Maximum outer diameter: 3.2 mm
- Approximate weight: 20 kg/km
FLAMEX EN 50264-3-1 600V 1.5 M GNYE
Nexans ref. 79462311
- Packaging: Spool (1000m)
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 2.8 mm
- Maximum outer diameter: 3.2 mm
- Approximate weight: 20 kg/km
FLAMEX EN 50264-3-1 600V 2.5 M
Nexans ref. 79462401
- Packaging: Spool (1000m)
- Conductor cross-section: 2.5 mm²
- Minimum outer diameter: 3.2 mm
- Maximum outer diameter: 3.6 mm
- Approximate weight: 29 kg/km
FLAMEX EN 50264-3-1 600V 2.5 M GNYE
Nexans ref. 79462411
- Packaging: Spool (1000m)
- Conductor cross-section: 2.5 mm²
- Minimum outer diameter: 3.2 mm
- Maximum outer diameter: 3.6 mm
- Approximate weight: 29 kg/km
FLAMEX EN 50264-3-1 600V 4 M
Nexans ref. 79462501
- Packaging: Spool (1000m)
- Conductor cross-section: 4 mm²
- Minimum outer diameter: 3.9 mm
- Maximum outer diameter: 4.3 mm
- Approximate weight: 44 kg/km
FLAMEX EN 50264-3-1 600V 4 M GNYE
Nexans ref. 79462511
- Packaging: Spool (1000m)
- Conductor cross-section: 4 mm²
- Minimum outer diameter: 3.9 mm
- Maximum outer diameter: 4.3 mm
- Approximate weight: 43 kg/km
FLAMEX EN 50264-3-1 600V 6 M
Nexans ref. 79462601
- Packaging: Spool (1000m)
- Conductor cross-section: 6 mm²
- Minimum outer diameter: 4.4 mm
- Maximum outer diameter: 4.8 mm
- Approximate weight: 62 kg/km
FLAMEX EN 50264-3-1 600V 6 M GNYE
Nexans ref. 79462611
- Packaging: Spool (1000m)
- Conductor cross-section: 6 mm²
- Minimum outer diameter: 4.4 mm
- Maximum outer diameter: 4.8 mm
- Approximate weight: 65 kg/km
FLAMEX EN 50264-3-1 600V 10 M
Nexans ref. 79462701
- Packaging: Spool (1000m)
- Conductor cross-section: 10 mm²
- Minimum outer diameter: 5.5 mm
- Maximum outer diameter: 5.9 mm
- Approximate weight: 102 kg/km
FLAMEX EN 50264-3-1 600V 10 M GNYE
Nexans ref. 79462711
- Packaging: Spool (1000m)
- Conductor cross-section: 10 mm²
- Minimum outer diameter: 5.5 mm
- Maximum outer diameter: 5.9 mm
- Approximate weight: 105 kg/km
FLAMEX EN 50264-3-1 600V 16 M
Nexans ref. 79462801
- Packaging: Spool (1000m)
- Conductor cross-section: 16 mm²
- Minimum outer diameter: 6.5 mm
- Maximum outer diameter: 7.1 mm
- Approximate weight: 161 kg/km
FLAMEX EN 50264-3-1 600V 16 M GNYE
Nexans ref. 79462811
- Packaging: Spool (1000m)
- Conductor cross-section: 16 mm²
- Minimum outer diameter: 6.5 mm
- Maximum outer diameter: 7.1 mm
- Approximate weight: 170 kg/km
FLAMEX EN 50264-3-1 600V 25 M
Nexans ref. 79462901
- Packaging: Spool (1000m)
- Conductor cross-section: 25 mm²
- Minimum outer diameter: 8.4 mm
- Maximum outer diameter: 9.0 mm
- Approximate weight: 248 kg/km
FLAMEX EN 50264-3-1 600V 25 M GNYE
Nexans ref. 79462911
- Packaging: Spool (1000m)
- Conductor cross-section: 25 mm²
- Minimum outer diameter: 8.4 mm
- Maximum outer diameter: 9.0 mm
- Approximate weight: 260 kg/km
FLAMEX EN 50264-3-1 600V 35 M
Nexans ref. 79463001
- Packaging: Spool (1000m)
- Conductor cross-section: 35 mm²
- Minimum outer diameter: 9.4 mm
- Maximum outer diameter: 10.0 mm
- Approximate weight: 326 kg/km
FLAMEX EN 50264-3-1 600V 35 M GNYE
Nexans ref. 79463011
- Packaging: Spool (1000m)
- Conductor cross-section: 35 mm²
- Minimum outer diameter: 9.4 mm
- Maximum outer diameter: 10.0 mm
- Approximate weight: 360 kg/km
FLAMEX EN 50264-3-1 600V 50 M
Nexans ref. 79463101
- Packaging: Spool (1000m)
- Conductor cross-section: 50 mm²
- Minimum outer diameter: 11.3 mm
- Maximum outer diameter: 11.9 mm
- Approximate weight: 477 kg/km
FLAMEX EN 50264-3-1 600V 50 M GNYE
Nexans ref. 79463111
- Packaging: Spool (1000m)
- Conductor cross-section: 50 mm²
- Minimum outer diameter: 11.3 mm
- Maximum outer diameter: 11.9 mm
- Approximate weight: 550 kg/km
FLAMEX EN 50264-3-1 600V 70 M
Nexans ref. 79463201
- Packaging: Spool (1000m)
- Conductor cross-section: 70 mm²
- Minimum outer diameter: 13.2 mm
- Maximum outer diameter: 13.8 mm
- Approximate weight: 666 kg/km
FLAMEX EN 50264-3-1 600V 70 M GNYE
Nexans ref. 79473211
- Packaging: Spool (1000m)
- Conductor cross-section: 70 mm²
- Minimum outer diameter: 13.2 mm
- Maximum outer diameter: 13.8 mm
- Approximate weight: 750 kg/km
FLAMEX EN 50264-3-1 600V 95 M
Nexans ref. 79463301
- Packaging: Spool (1000m)
- Conductor cross-section: 95 mm²
- Minimum outer diameter: 15.0 mm
- Maximum outer diameter: 15.6 mm
- Approximate weight: 868 kg/km
FLAMEX EN 50264-3-1 600V 95 M GNYE
Nexans ref. 79463311
- Packaging: Spool (1000m)
- Conductor cross-section: 95 mm²
- Minimum outer diameter: 15.0 mm
- Maximum outer diameter: 15.6 mm
- Approximate weight: 1000 kg/km
FLAMEX EN 50264-3-1 600V 120 M
Nexans ref. 79463401
- Packaging: Spool (1000m)
- Conductor cross-section: 120 mm²
- Minimum outer diameter: 16.7 mm
- Maximum outer diameter: 17.3 mm
- Approximate weight: 1106 kg/km
FLAMEX EN 50264-3-1 600V 120 M GNYE
Nexans ref. 79463411
- Packaging: Spool (1000m)
- Conductor cross-section: 120 mm²
- Minimum outer diameter: 16.7 mm
- Maximum outer diameter: 17.3 mm
- Approximate weight: 1250 kg/km
FLAMEX EN 50264-3-1 600V 150 M
Nexans ref. 79463501
- Packaging: Spool (1000m)
- Conductor cross-section: 150 mm²
- Minimum outer diameter: 18.7 mm
- Maximum outer diameter: 19.3 mm
- Approximate weight: 1390 kg/km
FLAMEX EN 50264-3-1 600V 150 M GNYE
Nexans ref. 79463511
- Packaging: Spool (1000m)
- Conductor cross-section: 150 mm²
- Minimum outer diameter: 18.7 mm
- Maximum outer diameter: 19.3 mm
- Approximate weight: 1540 kg/km
FLAMEX EN 50264-3-1 600V 185 M
Nexans ref. 79463601
- Packaging: Spool (1000m)
- Conductor cross-section: 185 mm²
- Minimum outer diameter: 21.0 mm
- Maximum outer diameter: 21.6 mm
- Approximate weight: 1689 kg/km
FLAMEX EN 50264-3-1 600V 185 M GNYE
Nexans ref. 79463611
- Packaging: Spool (1000m)
- Conductor cross-section: 185 mm²
- Minimum outer diameter: 21.0 mm
- Maximum outer diameter: 21.6 mm
- Approximate weight: 1880 kg/km
FLAMEX EN 50264-3-1 600V 240 M
Nexans ref. 79463701
- Packaging: Spool (1000m)
- Conductor cross-section: 240 mm²
- Minimum outer diameter: 23.8 mm
- Maximum outer diameter: 24.6 mm
- Approximate weight: 2178 kg/km
Description
Description
Standards
-
ProductEN 50264-3-1; EN 45545 - HL3; IEC 60228
DESIGN
1. Conductor
Flexible stranded tinned copper class 5 acc. to IEC 60228
Optional halogen-free separator tape
2. Insulation
Cross-linked compound type EI 109 acc. to EN 50264-3-1
Oil, diesel, ozone and UV resistant
Colour: black (or optionally green/yellow for earthing wires)
Example of marking: FLAMEX EN 50264-3-1 600V mm² M (N)HXAF 0,6/1kV I LYNXEO I WW-YYYY
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius:
- Static use: 3 x outer cable diameter
- For installation and occasional movements: 5 x outer cable diameter
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania