FLAMEX® EN 50382-2 FF

Products

FLAMEX SI EN 50382-2 1800V 120 FF 120°C

Nexans ref. 10260585

  • Packaging: m (1000m)
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 1800V 150 FF 120°C

Nexans ref. 10198408

  • Packaging: m (1000m)
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 1800V 185 FF 120°C

Nexans ref. 10260584

  • Packaging: m (1000m)
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 1800V 240 FF 120°C

Nexans ref. 10217649

  • Packaging: m (1000m)
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 1800V 50 FF 120°C

Nexans ref. 10260587

  • Packaging: m (1000m)
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 1800V 70 FF 120°C

Nexans ref. 10260586

  • Packaging: m (1000m)
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 1800V 95 FF 120°C

Nexans ref. 10198407

  • Packaging: m (1000m)
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV

 

FLAMEX SI EN 50382-2 3600V 120 FF 120°C

Nexans ref. 10211471

  • Packaging: m (1000m)
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 150 FF 120°C

Nexans ref. 10211472

  • Packaging: m (1000m)
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 185 FF 120°C

Nexans ref. 10211473

  • Packaging: m (1000m)
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 240 FF 120°C

Nexans ref. 10211474

  • Packaging: m (1000m)
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 50 FF 120°C

Nexans ref. 10211468

  • Packaging: m (1000m)
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 70 FF 120°C

Nexans ref. 10211469

  • Packaging: m (1000m)
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

FLAMEX SI EN 50382-2 3600V 95 FF 120°C

Nexans ref. 10211470

  • Packaging: m (1000m)
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

Description

Description

Standards

  • Product
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

DESIGN

 

1. Conductor
Flexible class 5 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class
Separator: Unweaved tape

2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1

3. Outer sheath
Cross-linked silicone type EM 107 according to EN 50382-1
Colour: black outer layer

Example of marking: FLAMEX SI - EN 50382-2  - Voltage rate (1800V or 3600V) - cross-section mm² - FF - temperature class (120°C or 150°C) - LYNXEO 279 - week/year

GUIDE TO USE

 

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 4 x outer cable diameter
    • For installation and occasional movements: 6 x outer cable diameter
  • Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
  • Mechanical static tensible force: 15N/mm² of copper size

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tin plated copper
Conductor flexibility
Flexible class 5
Insulation
High temperature silicone
Outer sheath
High temperature silicone
Halogen free
EN 60754-1 & EN 60684-2

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 ... 120 °C
Max. conductor temperature in service
120 °C
Overload maximum core temperature
140 °C
Chemical resistance
Good

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close