ALSECURE-K 1x16 Brown P4.2 R100

Description

Description

Standards

  • Product
    EN 50525-3-31; EN 50575; IEC 60228; UNE 21022; UNE 211002
  • Test
    EN 50266-2-4; EN 50267-2-2; IEC 60332-1; IEC 60332-3-24; IEC 61034-2; NF C32-070/C2; UNE EN 50267-2-3 ; UNE-EN 50265-2-1

Application

Flexible insulated conductors Nexans H07Z1-K are used for fixed secured protected installation.
Halogen free, fire retardant with low emission of smoke, Nexans H07Z1-K may be used in public buildings or areas where fire safety is concerned
 

Installation
Nexans H07Z1-K
can be installed in open air, in conduit, in cable ducting, in switch cabinets.
Thanks to the sliding properties of the insulation, installation is made easier while pulling in...
 

Encuentra este producto en EASYCALC™

New cardboard packaging for H07V-K and H07Z1-K

Color code for Nexans Alsecure H07Z1-K cross-section

Cable colors available

-

-

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Flexible class 5
Conductor material
Bare copper
Insulation
Halogen free, TI 7 acc. EN 50363-7
Lead free
Yes
Halogen free
Yes
Conductor shape
Circular
Insulation colour
Brown
With Green/Yellow core
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
16 mm²
Approximate weight
175 kg/km
Neutral conductor section (when smaller)
- mm²
Number of cores
1
Outer Diameter
7.2 mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
450/750 V
Max. DC resistance of the conductor at 20°C
1.21 Ohm/km
Maximum operating voltage
750 V
Permissible current rating in open air
76 A
Test voltage
2500 V

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Flexible
Mechanical resistance to impacts
Low

Usage characteristics

Usage characteristics

Max. conductor temperature in service
70 °C
Fire retardant
EN IEC 60332-3-24 (cat C)
Flame retardant
EN 50265-2-1
Smoke density
EN 50268-2
Chemical resistance
Restricted to oil, acid & base
Maximum operating temperature
70 °C
Packaging
Coil
Water proof
Limited
Weather resistance
Restricted, not ozon stable

Resources

Resources

Documentation

H07Z1-K PEP pdf — 4.3 MB
CMC H07Z1-K pdf — 778.9 kB

Current capacity table PVC insulation multicore three phase

Conductor cross-section A2 - Multi-core cable in conduit in a thermally insulated wall B2 - Multi-core cable in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground E - Multi-core cable in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
16.0 52.0 41.0 62.0 48.0 76.0 59.0 64.0 50.0 70.0 53.0 80.0 61.0

Current capacity table PVC insulation multicore single phase

Conductor cross-section A2 - Multi-core cable in conduit in a thermally insulated wall B2 - Multi-core cable in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground E - Multi-core cable in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
16.0 57.0 44.0 69.0 54.0 85.0 66.0 78.0 61.0 83.0 63.0 94.0 73.0

Current capacity table PVC insulation single core three phase

Conductor cross-section A1 - Insulated conductors in conduit in a thermally insulated wall B1 - Insulated conductors in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground F - Single-core flat cables, touching in free air Ft - Single-core trefoil cables, touching in free air G - Single-core horizontal spaced Gv - Single-core flat vertical spaced
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
16.0 56.0 43.0 68.0 53.0 76.0 59.0 64.0 50.0 70.0 53.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Current capacity table PVC insulation single core single phase

Conductor cross-section A1 - Insulated conductors in conduit in a thermally insulated wall B1 - Insulated conductors in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground F - Single-core flat cables, touching in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
16.0 61.0 48.0 76.0 60.0 85.0 66.0 78.0 61.0 83.0 63.0 0.0 0.0

Selling & delivery Information

Ink jet marking
USE - HAR- ALSECURE H07Z1-K (AS) TYPE 2 AENOR PLANT N° NEXANS – DAY YEAR

Declaration of Performance

  • Declaration of Performance n� : 1000150-FRAU
  • Certification Date : 1/28/21
  • AVCP (Assessment and Verification of Constancy of Performance) : System 1+
  • Notified body : NB 099
  • Declared performance : Cca-s1b,d1,a1

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close