ALSECURE® RZ1-K (AS) 4x50
ALSECURE® RZ1-K (AS) 4x50
ALSECURE 1KV
Read more- Nexans ref. : 10271801
- Country ref. : 3427580766794
Description
Description
Standards
-
ProductIEC 60502; UNE 21123
-
TestEN 50265-2-1; EN 50267-2-2; EN 50268; IEC 60332-1; IEC 60332-3 Cat.C; IEC 60754-1; IEC 60754-2; IEC 61034
Application
RZ1-K Cable NON PROPAGATOR OF FIRE.
Installation in local of difficult ventilation, publics, evacuation itineraries, tunnels...
Almost null toxicity. Provoked gases when burning almost transparent, facilitating evacuation.
Core colours
- 1 core = Black
- 2 cores = Brown + Light blue
- 3 cores = Brown + Black + Grey or Brown + Light blue + Green-Yellow
- 4 cores = Brown + Black + Grey + Light blue or Green-Yellow
- 5 cores = Brown + Black + Grey + Light blue + Black or Green-Yellow
Marking
ALSECURE ® Nexans RZ1 - K(AS) -0,6/1 KV - N (x or G) S mm² - Fab.Year- AENOR
- N = number of cores
- S = section in mm²
- G = with Green-Yellow
- x = without Green-Yellow
RZ1-K 4X
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Electrolytic copper
Sheath colour
Green
Outer sheath
Polyolefin
Insulation
Extruded XLPE compound
Conductor flexibility
Flexible class 5
Conductor shape
Circular
Halogen free
IEC 60754-1
Lead free
Yes
With Green/Yellow core
No
With smaller neutral conductor
No
Dimensional characteristics
Dimensional characteristics
Number of cores
4
Conductor cross-section
50 mm²
Approximate weight
2415 kg/km
Neutral conductor section (when smaller)
- mm²
Outer Diameter
32.7 mm
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
0,6/1 kV
Max. DC resistance of the conductor at 20°C
- Ohm/km
Permissible current rating in open air
- A
Permissible current rating when buried
- A
Usage characteristics
Usage characteristics
Max. conductor temperature in service
90 °C
Fire retardant
IEC 60332-3-24 (cat C)
Flame retardant
IEC 60332-3 Cat. C
Gases corrosivity
IEC 60754-2
Packaging
-
Smoke density
IEC 61034-2
Weather resistance
Good
Resources
Resources
Documentation
PEP ECOPASSPORT RZ1-K 1.5 and 2.5 mm²
pdf — 4.4 MB
BROCHURE MOBIWAY MOB
pdf — 3.8 MB
PEP ECOPASSPORT RZ1-K MULTI
pdf — 5.1 MB
PEP ECOPASSPORT RZ1-K MONO
pdf — 5.1 MB
Current capacity table XLPE insulation multicore three phase
Conductor cross-section | A2 - Multi-core cable in conduit in a thermally insulated wall | B2 - Multi-core cable in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | E - Multi-core cable in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
50.0 | 130.0 | 115.0 | 154.0 | 138.0 | 179.0 | 154.0 | 164.0 | 128.0 | 153.0 | 139.0 | 225.0 | 164.0 |
Current capacity table XLPE insulation single core three phase
Conductor cross-section | A1 - Insulated conductors in conduit in a thermally insulated wall | B1 - Insulated conductors in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | F - Single-core flat cables, touching in free air | Ft - Single-core trefoil cables, touching in free air | G - Single-core horizontal spaced | Gv - Single-core flat vertical spaced | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
50.0 | 141.0 | 113.0 | 175.0 | 140.0 | 179.0 | 136.0 | 135.0 | 106.0 | 153.0 | 117.0 | 216.0 | 159.0 | 207.0 | 275.0 | 159.0 | 210.0 | 246.0 | 188.0 |
Current capacity table XLPE insulation single core single phase
Conductor cross-section | A1 - Insulated conductors in conduit in a thermally insulated wall | B1 - Insulated conductors in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | F - Single-core flat cables, touching in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
50.0 | 158.0 | 125.0 | 198.0 | 157.0 | 209.0 | 154.0 | 164.0 | 128.0 | 183.0 | 139.0 | 242.0 | 184.0 |
Current capacity table XLPE insulation multicore single phase
Conductor cross-section | A2 - Multi-core cable in conduit in a thermally insulated wall | B2 - Multi-core cable in conduit on a wooden wall | C - Single-core or multi-core cable on a wooden wall | D1 - Single-core or Multi-core cable in ducts in the ground | D2 - Single-core or Multi-core cables designed to be buried directly in the ground | E - Multi-core cable in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
50.0 | 145.0 | 115.0 | 175.0 | 138.0 | 209.0 | 154.0 | 164.0 | 128.0 | 183.0 | 139.0 | 225.0 | 164.0 |
Declaration of Performance
- Declaration of Performance n� : 1000335-ESPO
- Certification Date : 12/1/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 1+
- Notified body : NB 0099
- Declared performance : Cca-s1b,d1,a1