ALSECURE® RZ1-K (AS), 3G10 mm²

Description

Description

Standards

  • Product
    IEC 60502; UNE 21123
  • Test
    EN 50265-2-1; EN 50267-2-2; EN 50268; IEC 60332-1; IEC 60332-3 Cat.C; IEC 60754-1; IEC 60754-2; IEC 61034

Application

RZ1-K Cable NON PROPAGATOR OF FIRE.  
Installation in local of difficult ventilation, publics, evacuation itineraries, tunnels... 

 
Almost null toxicity. Provoked gases when burning almost transparent, facilitating evacuation.

Core colours

  • 1 core =  Black
  • 2 cores = Brown + Light blue
  • 3 cores = Brown + Black + Grey   or  Brown + Light blue + Green-Yellow
  • 4 cores = Brown + Black + Grey + Light blue or Green-Yellow
  • 5 cores = Brown + Black + Grey + Light blue + Black or Green-Yellow

Marking

ALSECURE ® Nexans RZ1 - K(AS) -0,6/1 KV - N (x or G) S mm² - Fab.Year- AENOR

  • N = number of cores
  • S = section in mm²
  • G = with Green-Yellow
  • x = without Green-Yellow

MOB

ALSECURE - Protección ante el fuego

Gama compatible con MOBIWAY

PHOTO AMBIANCE 1

PHOTO AMBIANCE 2

Photo Ambiance

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Electrolytic copper
Sheath colour
Green
Outer sheath
Polyolefin
Insulation
Extruded XLPE compound
Conductor flexibility
Flexible class 5
Conductor shape
Circular
Halogen free
IEC 60754-1
Lead free
Yes
With Green/Yellow core
Yes
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Conductor cross-section
10 mm²
Approximate weight
530 kg/km
Neutral conductor section (when smaller)
- mm²
Outer Diameter
20.3 mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV
Max. DC resistance of the conductor at 20°C
- Ohm/km
Permissible current rating in open air
75 A
Permissible current rating when buried
60 A

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Fire retardant
IEC 60332-3-24 (cat C)
Flame retardant
IEC 60332-3 Cat. C
Gases corrosivity
IEC 60754-2
Packaging
-
Smoke density
IEC 61034-2
Weather resistance
Good

Resources

Resources

Current capacity table XLPE insulation multicore three phase

Conductor cross-section A2 - Multi-core cable in conduit in a thermally insulated wall B2 - Multi-core cable in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground E - Multi-core cable in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
10.0 51.0 45.0 60.0 54.0 71.0 62.0 71.0 55.0 65.0 0.0 86.0 67.0

Current capacity table XLPE insulation single core three phase

Conductor cross-section A1 - Insulated conductors in conduit in a thermally insulated wall B1 - Insulated conductors in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground F - Single-core flat cables, touching in free air Ft - Single-core trefoil cables, touching in free air G - Single-core horizontal spaced Gv - Single-core flat vertical spaced
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
10.0 54.0 44.0 66.0 52.0 71.0 57.0 58.0 46.0 65.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Current capacity table XLPE insulation single core single phase

Conductor cross-section A1 - Insulated conductors in conduit in a thermally insulated wall B1 - Insulated conductors in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground F - Single-core flat cables, touching in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
10.0 61.0 48.0 75.0 59.0 80.0 62.0 71.0 55.0 77.0 0.0 0.0 0.0

Current capacity table XLPE insulation multicore single phase

Conductor cross-section A2 - Multi-core cable in conduit in a thermally insulated wall B2 - Multi-core cable in conduit on a wooden wall C - Single-core or multi-core cable on a wooden wall D1 - Single-core or Multi-core cable in ducts in the ground D2 - Single-core or Multi-core cables designed to be buried directly in the ground E - Multi-core cable in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
10.0 57.0 45.0 69.0 54.0 80.0 62.0 71.0 55.0 77.0 0.0 86.0 67.0

Declaration of Performance

  • Declaration of Performance n� : 1000335-ESPO
  • Certification Date : 10/28/21
  • AVCP (Assessment and Verification of Constancy of Performance) : System 1+
  • Notified body : NB 0099
  • Declared performance : Cca-s1b,d1,a1

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close